Overview

Pultruded carbon fibre T profile. A T-section, also called a t-shaped profile in the trade, 20–150 mm deep, 20–100 mm flange width, wall thickness 2–6 mm, cut to length. One flange and one web. The flat of the flange takes a panel, a frame or an existing structure. The web stands up to carry bending. Depth and flange tolerance ±0.2 mm (±0.3 mm above 100 depth), flange symmetry ≤0.5 mm. The table gives weight per metre and second moment of area: 100×50×5 is 1.12 kg/m with Ix 76.7 cm⁴. 150×100×6 is 2.27 kg/m with Ix 348.7 cm⁴. Second moment of area and neutral axis position are both calculated, and can be recomputed from the section dimensions. The same profile can be supplied as a machined part: custom composite parts.

Request a quote

Where it is used

  • Stiffeners on the back of flat panels and covers
  • Enclosure and cabinet frames, including corners
  • Reinforcing edges for door frames and access openings
  • Stiffeners for platforms and floors
  • Equipment bases and support ribs
  • One-sided reinforcement of existing panels

Stock sizes in detail

Read it as depth × flange × wall. A T has one flange, so the neutral axis is off-centre — the table gives its position; fitted upside down it carries roughly half.

Code Depth×flange Wall Length Weight kg/m Ix cm⁴ Tolerance Note
TB-20-20-2 20×20 2 1000 0.12 0.3 ±0.2 Small panel stiffening
TB-25-25-2.5 25×25 2.5 1000 0.18 0.7 ±0.2 Cover stiffener
TB-30-30-3 30×30 3 1000 0.27 1.5 ±0.2 Enclosure stiffening
TB-40-40-3 40×40 3 1000 0.36 3.6 ±0.2 Panel stiffener
TB-50-40-4 50×40 4 1000 0.53 8.6 ±0.2 Edge frame
TB-50-50-3 50×50 3 1000 0.45 7.1 ±0.2 Panel stiffener
TB-50-50-5 50×50 5 1000 0.74 11.3 ±0.2 Load-bearing stiffener
TB-60-40-4 60×40 4 1000 0.60 14.3 ±0.2 Cabinet frame
TB-60-60-4 60×60 4 1000 0.72 16.3 ±0.2 Floor beam
TB-75-50-5 75×50 5 1000 0.93 34.9 ±0.2 Long stiffener
TB-80-60-5 80×60 5 1000 1.05 44.3 ±0.2 Platform stiffener
TB-80-80-5 80×80 5 1000 1.20 48.6 ±0.2 Platform stiffener
TB-100-50-5 100×50 5 1000 1.12 76.7 ±0.3 Main stiffener
TB-100-75-5 100×75 5 1000 1.32 88.2 ±0.3 Main stiffener
TB-100-100-5 100×100 5 1000 1.51 96.7 ±0.3 Structural reinforcement
TB-120-60-6 120×60 6 1000 1.62 159.1 ±0.3 Heavy-duty stiffener
TB-150-75-6 150×75 6 1000 2.04 315.9 ±0.3 To drawing, new die
TB-150-100-6 150×100 6 1000 2.27 348.7 ±0.3 To drawing, new die

Three dimensions: depth, flange width, wall

The trade writes 100×50×5. 100 deep, 50 flange width, 5 wall. The same order as the I beam. Depth decides bending. A T profile has only one flange, so bending rests almost entirely on the height of the web. Depth is the only dimension worth adding, and the table has the comparison at equal weight: 50×50×5 is 0.74 kg/m with Ix 11.3. 100×50×5 is 1.12 kg/m with Ix 76.7. Double the flange width instead to 50×100×5, same 1.12 kg/m, and Ix is only 13.6. Add depth, not width. Flange width decides two things: whether the flange face is wide enough, bonding area, bolt pattern. Whether the compression flange buckles first. On a panel stiffener the flange width goes with the stiffener spacing. Too narrow gives too little bond area; too wide leaves an exposed glue line that looks wrong. 40–75 is the common range. Wall governs web buckling and the local stability of the flange. The web of a T has one free edge, so it buckles more readily than an I beam's. The wall cannot be too thin: 2 mm suits small-section stiffeners only, and load-bearing starts at 3 mm.

The neutral axis is not in the middle

This is the biggest difference between a T profile and the other sections, and the place where a selection is most often miscalculated. Square tube, round tube and I beam are symmetric top and bottom, so the neutral axis sits exactly in the middle. A T has only one flange, material piles at one end, and the neutral axis is pulled towards it. The neutral axis depth from the flange face is:

yc = (B·t + H² − t²) / (2(B + H − t))
with B the flange width, H the section depth and t the wall. Three rows from the table:
  • 100×50×5: yc = 35.3 mm, depth 100 — the neutral axis sits at 35% of the height
  • 100×100×5: yc = 26.9 mm — widen the flange to 100 and the neutral axis drops to 27%
  • 150×100×6: yc = 47.3 mm, depth 150 — 32% of the height
A neutral axis close to the flange has two consequences: Small compression zone, large tension zone. With the flange on the compression side, the compression zone is only yc deep, and carbon fibre is weaker in compression than in tension, so that split is favourable. Turn the flange to the tension side and the compression zone becomes H−yc, 65, 73 and 103 mm in the three rows above. Compression suddenly acts on a tall thin web, and the problem moves to the next section. The neutral axis moves with flange width. A wider flange pulls the neutral axis towards the flange. Looks like adding material but flattens the compression zone and lengthens the tension zone. So widening the flange on a T is not a free gain; it has to be read together with the depth. If you remember one thing: choose a T profile by depth rather than by flange width.

Which way up the flange faces decides the load capacity

Second moment of area is pure geometry. The same number whichever way up the profile is fitted. But the compression side changes, and whether it can carry the moment is a different question entirely. Flange up (normal orientation) The flange is in compression. Supported continuously by the web, it behaves like a plate supported on two edges, and buckling has to overcome the restraint of the web. The critical stress is high. This is how a T profile is meant to be used, stiffeners, edge frames and door frames all run this way. Flange down (inverted) The web tip is in compression. With one free edge it is a cantilever plate with no lateral restraint, and it bends sideways the moment it is loaded. At the same Ix, the moment it can carry inverted is far below the normal orientation. That is not a strength shortfall, it is a stability shortfall: the section buckles before the material reaches its limit. So put the flange on the compression side. On a panel stiffener, with the panel below and the rib above, the flange sits against the panel and load passes from panel to rib. Puts the flange on the compression side. The right way up. Reverse it, rib above the panel with the flange up, and the load path is wrong. An inverted fit is structurally unavoidable, space limits, or hanging from below, give us span. Load and support conditions and we work out the buckling margin for the inverted case. If it does not come out, go to an I beam or a deeper section. Do not settle that one by experience.

Panel stiffening: the most underrated use of a T

Where a carbon fibre sheet is used as a large panel, its thickness is usually limited by weight and its bending is not enough. The answer is not a thicker panel, it is stiffeners bonded to the back. A T profile has exactly the right shape for the job. The flat of the flange goes against the back of the panel, and the web stands up. The panel is divided into small bays, the effective span of each bay shrinks. Panel bending improves with the square of the span, halve the span and stiffness goes up four times. That is the whole logic of a stiffener. A few things to get right. Bond, do not rely on bolts. The underside of the flange is bonded to the panel, bond line 0.2–0.5 mm, clamped cure. Carbon fibre sheet against a T profile is a face-to-face joint, so the load spreads far more evenly than through bolted point connections. No holes are cut in the panel to weaken the section. Where a mechanical fixing is wanted, use bolts at the ends for location and to stop it lifting; the bond line still carries the load. The flange face has to be prepared. A pultruded surface is smooth and release agent residue will destroy the bond. The face needs abrading or blasting; we can prepare it as a bonding face at the factory if you say so when ordering. Stiffener spacing follows the panel bays. Denser is not better, beyond a point the weight eats the gain. The usual approach is to aim for bays close to square, then work the spacing back from the allowed deflection. The ends need closing off. Do not leave a stiffener ending in mid-air: run it into a frame, or taper the end. A free end is a stress concentration and the first place that lifts. This section belongs with the carbon fibre sheet page: the sheet sets the panel thickness, the T profile sets the stiffening. The two are chosen together.

Weight per metre, and how it compares

Carbon fibre at 1.55 and steel at 7.85 gives about an 80% reduction at equal volume. Every band in the table carries kg/m:

  • 50×50×5: 0.74 kg/m
  • 100×50×5: 1.12 kg/m
  • 150×100×6: 2.27 kg/m
Against the I beam. At the same depth, width and wall, an I beam has about 1.8 times the second moment of area of a T (100×50×5: T 76.7, I 143.3) for about 30% more weight. Measured as bending efficiency per unit weight, the I wins. The T's advantage is not efficiency but use: one flange only, so it can be bonded to an existing face and takes half the space. To go against a panel, a frame, or a structure already built: T. To have fittings on both faces and stand alone as a beam: I. Against steel and aluminium. Modulus depends on fibre grade and fibre volume fraction, so we do not publish one number. The conversion method is settled. Aluminium at about 70 GPa is close to pultruded carbon. At the same size it usually substitutes directly and the carbon part is lighter. Check bearing and compression at the connections, since aluminium yields where carbon is brittle. Steel at 210 GPa is the hard case, always softer at the same size. Works back from I_carbon = I_steel × 210 / E_carbon, in practice by adding depth rather than wall. Use the data for your chosen layup for E_carbon. Against a solid rectangle. At equal weight, a solid bar has an order of magnitude less second moment of area than a T. A T moves material from the middle out to the edges; that is the reason it exists.

Length, cutting and end facing

Standard lengths are 1000 mm and 2000 mm, with other lengths cut to order; longer needs a joint. Cutting. Water-jet leaves a clean edge without chipping, the first choice for thin wall and visible parts. Thick wall and long runs take sawing, leaving 0.2 mm on the end to machine back. End squareness ±0.5°. A T profile end is the flange end face plus the web tip. The flange end face is easy to hold square; the web tip is thin and drifts when cut. For door frames and edge frames, mark it: a web tip 1 mm out shows as a gap at the mitre. Protect the web tip. On a thin-wall T the web end is the most fragile part. A knock in transit or assembly leaves a notch, which starts a crack. On long lengths we fit corner protection; on short lengths, cut the ends again before assembly.

Delivery states

  • Natural The pultruded surface as it comes: smooth, dark grey to black, unpatterned. The default for structural and internal parts.
  • Clear coat A coat over the natural surface, gloss or semi-matte. More resistant to soiling.
  • Matte The same coating system, flattened; less reflection, common on exposed edge frames and display work.
  • Painted Painted to a project colour reference; the colour and the gloss are yours, and we control flatness and adhesion.

Tolerance and inspection

Depth (≤100 mm) ±0.2 mm Calliper + dimensional report
Depth (>100 mm) ±0.3 mm Calliper
Flange width ±0.2 mm Calliper
Wall thickness ±5% (thin wall counted by plies) Calliper / ultrasonic
Flange to web squareness 90° ±0.5° Engineer's square + feeler gauge
Flange symmetry ≤0.5 mm Surface plate + height gauge
Flange face flatness ≤0.3 mm / 100 mm Surface plate + feeler gauge
Inside radius Determined by the wall thickness (of the same order) Profile gauge / projector
Straightness 1 mm / m Surface plate + feeler gauge
Twist ≤1° / m Surface plate measurement
Length (cut to length) ±0.1 mm Water-jet guided / CNC
End squareness ≤0.5° Engineer's square
Hole position and slotting ±0.01 mm CMM

Common questions

T profile or I beam — which should I choose?

Look at whether both faces need fittings. An I beam has a flange top and bottom, so it stands alone as a beam and fixes at both ends; a T has one flange, so it goes against an existing face, reinforces one side, and takes half the space. At the same size an I beam bends about 1.8 times better for 30% more weight, so the I is more efficient; the T's advantage is that it can be bonded on

Is a T profile the same as a T beam?

The section is the same — one flange, one web. The name is not. T profile and T section are how the trade describes the section, and competitors' pages use them; T beam is structural engineering usage, but its SERP mixes servo press line equipment, machine tool beams and steel T beams, so searching on it does not land on profiles. Search T profile and you land on profile makers

Why is the neutral axis not in the middle?

There is only one flange, so the material piles on one side. yc = (B·t + H² − t²) / (2(B + H − t)): the wider the flange and the thicker the wall, the closer the neutral axis comes to the flange. 100×50×5 puts it at 35% of the depth, 100×100×5 at 27%. Select on depth, not on flange width

Can it be fitted the other way up?

It can be fitted, but the load case has to be recomputed. The second moment of area is unchanged, while the compression side moves from the flange to the web tip. With one free edge the web is a cantilever plate, so the buckling stress is far below that of a flange supported on two edges, and the moment it can carry at the same Ix drops a long way. Where an inverted fit is unavoidable, give us span, load and support conditions and we work the buckling out for that orientation

Does a wider flange increase bending capacity?

Not at equal weight. 50×50×5 is 0.74 kg/m with Ix 11.3; double the flange width to 50×100×5 and it is 1.12 kg/m with Ix 13.6 — half as much weight again for 20% more second moment of area. Depth is what works: 100×50×5, at the same 1.12 kg/m, gives Ix 76.7

How do I bond a panel stiffener?

Bond the underside of the flange to the panel, bond line 0.2–0.5 mm, clamped cure. The flange face has to be abraded or blasted to remove release agent — ask for bonding-face preparation when ordering. Bolts at the ends locate the rib only; the bond line carries the load. Run both ends into a frame rather than stopping in mid-air

Is the flange face flat?

Held to 0.3 mm / 100 mm. On a bonded part this figure matters more than the outside dimensions: an uneven face gives an uneven bond line, and the joint starts to fail at the thinnest point. Ask for it separately on a stiffener job

Can you drill and tap it?

Drilling, notching and counterboring, all at ±0.01 mm. Carbon fibre is not threaded: for a bolted joint use through bolts with washers, or bond an insert in. When drilling a T profile, keep the holes clear of the radius where the web meets the flange

Is there any carbon weave?

No. Pultrusion gives a unidirectional finish — a layer of resin, dark grey to black. Carbon weave means overwrapping 3K prepreg, or changing to a moulded part

What are the MOQ and lead time?

300 pcs. Normal batches ship in 15–20 days; a non-standard depth, flange or wall, or an unequal section, needs a die, which takes 5–7 days

Can you make glass fibre?

Yes, in the same construction — lower stiffness and lower cost, common for insulating parts and low-frequency structural parts. Quoted through the glass fibre product line

Send us the size

Section, length, quantity and service conditions — with these in hand the quote is accurate. Upload a drawing if you have one; without one, the same figures written out will do.

No file selected

PDF, DWG, DXF, STEP, STL, ZIP or a phone photo — up to 20 MB.

The part, the material, the size — or the problem it has to solve. Drawings and photos can go in the field above.

+ Company, quantity, timeline

Used only to answer this enquiry and for related technical follow-up.

  • Company address Zhuyuan Tianhuan International, No. 76 Keji 2nd Road, High-tech Zone, Xi'an, Shaanxi, China
  • Factory Fengjing Industrial Park, Middle Section of Fengwu East Road, Huyi District, Xi'an, Shaanxi, China
  • Sales email sales@atomfrp.com
  • Phone (WeChat) +86 18191567691 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • WhatsApp +853 68617664 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • A named engineer replies within 24 hours
  • NDA can be signed before any file is sent
  • Drawings and requirements are not disclosed

Send the drawing. We will send the route.

A drawing, a photo of a failed part, or three lines of requirement is enough to start. Scope, price indication and lead time within 24 hours.

No commitment · NDA available · Reply within 24 hours

Request a quote WhatsApp