Overview

Pultruded structural flat bar. A solid rectangular section with fibre running unidirectional along its length. Width 5–50 mm, thickness 0.5–10 mm, cut to length. The width-to-thickness ratio runs from 2:1 to 50:1. That ratio decides how many times stiffer the section is in one orientation than the other. The table gives both, laid flat and on edge. The first question in selection is which way the bar will be fitted, not how wide it is. For a finished part rather than a length of stock, the route is custom composite parts.

Request a quote

Where it is used

  • Stiffeners on the back of flat panels and sandwich panels
  • Diagonal bracing, tie bars and corner reinforcement in frames
  • Edge bars for enclosures, cabinets and door frames
  • Clamping strips and liners for slides and linear rails
  • Edge reinforcement for laminates
  • Structural parts for prototypes and tooling

Stock sizes in detail

The two second-moment columns are the point of this table: laid flat and on edge differ by (width ÷ thickness)². Settle the orientation first, then pick the size.

Code Width Thickness Section mm² kg/m I laid flat mm⁴ I on edge mm⁴ Note
FB-10-1 10 1 10 0.016 1 83 Facing reinforcement
FB-10-0.5 10 0.5 5 0.008 0.1 42 Thin facing strip
FB-10-2 10 2 20 0.031 7 167 Edge bar
FB-12-2 12 2 24 0.037 8 288 Edge bar
FB-15-2 15 2 30 0.047 10 563 General reinforcement
FB-15-3 15 3 45 0.070 34 844 Bracing
FB-20-1 20 1 20 0.031 2 667 Edge trim
FB-20-0.5 20 0.5 10 0.016 0.2 333 Edge trim, facing
FB-20-2 20 2 40 0.062 13 1,333 General stiffener
FB-20-3 20 3 60 0.093 45 2,000 General tie bar
FB-20-5 20 5 100 0.155 208 3,333 Load-bearing tie bar
FB-25-3 25 3 75 0.116 56 3,906 Frame bracing
FB-25-5 25 5 125 0.194 260 6,510 Load-bearing bracing
FB-30-3 30 3 90 0.140 68 6,750 Long-span tie bar
FB-30-0.5 30 0.5 15 0.023 0.3 1,125 Edge trim, wrapping
FB-30-5 30 5 150 0.233 313 11,250 Load-bearing cross brace
FB-40-4 40 4 160 0.248 213 21,333 Main edge bar
FB-40-6 40 6 240 0.372 720 32,000 Load-bearing edge bar
FB-50-1 50 1 50 0.078 4 10,417 Edge banding, wrapping
FB-50-0.5 50 0.5 25 0.039 0.5 5,208 Wrapping, edge banding
FB-50-5 50 5 250 0.388 521 52,083 Large-span tie bar
FB-50-8 50 8 400 0.620 2,133 83,333 Load-bearing main bar
FB-50-10 50 10 500 0.775 4,167 104,167 Heavy duty

How width, thickness and length fit together

The trade writes 20×3. 20 wide, 3 thick, in mm. The section is a solid rectangle with no inner wall. Width is the main variable in bending, but only on edge, on edge the second moment follows the cube of the width. Double the width and stiffness goes up eight times. Laid flat, width enters only linearly and the gain is slow. This is the root difference from square tube: a square tube is closed on four sides and behaves much the same both ways. A flat bar differs by orders of magnitude. Thickness governs stiffness laid flat, where it enters as a cube, resistance to point load and local denting. The tightest curve the bar will take: the minimum bend radius is about 100 × the thickness. 0.5 mm takes a 50 mm radius and 5 mm needs 500 mm or more. That bend is elastic, held by bond and clamps, not set into the material. Below 1 mm the bar is really a flat strip. It will follow a tight radius, but has almost nothing sideways. Suits facing, edge trim and wrapping only. Width-to-thickness ratio is the number to read first. Below 2:1 the bar is close to a square bar, the orientations hardly differ. A square bar is both simpler and harder to fit the wrong way round. Above 20:1 a bar on edge is strong in bending and very weak sideways, so lateral support becomes part of the assembly. Length: Cut to the length you order. Cutting to 1000, 2000 or 3000 costs nothing extra; shorter lengths are charged per cut.

Stiffness depends on which way up it is fitted

This is the one thing to settle before anything else. Fitted one way or the other, the same bar differs in stiffness by (width ÷ thickness)².

FittedSecond momentLoad direction
Laid flatI = width × thickness³ ÷ 12wide face down, load normal to it
On edgeI = thickness × width³ ÷ 12narrow face down, load normal to it
The ratio of the two = (width ÷ thickness)². Some real numbers:
SizeWidth:thicknessI laid flat (mm⁴)I on edge (mm⁴)Ratio
20×210131,333100
30×310686,750100
50×51052152,083100
50×150410,4172,500
Look at the last row: at 50:1 the two orientations differ by 2,500 times. Laid flat, that bar hardly bends at all; on edge it is stiffer than a 50×5. The same stock, fitted differently, is two different parts. So before ordering, answer one question: does this bar go onto a face, or does it carry bending on its own? Onto a face, it goes flat. Carrying bending, it goes on edge. The two are not the same specification.

Flat or on edge

Laid flat: the wide face goes against the face being stiffened and is bonded or screwed. Stiffness is low, but the contact area is large and the fit is good, panel stiffeners, sealing strips, slide liners, edge trim. The value of a flat bar is not its own stiffness; it is tying two panels into one and spreading local load. On edge: the narrow face takes the load and stiffness is high, which suits tie bars, bracing and edge frames that carry bending themselves. The price is lateral instability in compression. Take a 6000 mm bar, 3 mm thick, stood on edge and unrestrained at mid-span. It twists sideways long before reaching the load its second moment suggests. Whether lateral support is needed turns on the unrestrained length divided by the thickness, not on the length alone. The larger that ratio, the worse it gets. Past a point the answers are a mid-span support, two bars fixed side by side, or square tube. Send the drawing with your span and load and we work it through before the order. Mixed use is the commonest form: several flat bars laid flat across the back of a panel as stiffeners, spaced to suit the panel span, costs far less than a thicker panel. Frame corners take bars on edge as bracing, with a cross brace at mid-span against sideways twist.

Weight per metre, against a steel bar of the same width

weight per metre kg/m = width (mm) × thickness (mm) × 1.55 ÷ 1000
SizeCarbon fibre kg/mSteel bar, same size kg/mLighter by
20×20.0620.31480%
30×30.1400.70680%
50×50.3881.96280%
The ratio is fixed: carbon fibre at 1.55 and steel at 7.85 gives 80% lighter at the same size, every time. The column does not need working out row by row, one number covers it. But the same size is not the same stiffness. Carbon fibre has a lower modulus than steel, so a straight substitution comes out softer. Equal stiffness works back from I_carbon = I_steel × 210 ÷ E_carbon, with 210 the published value for steel and E_carbon taken from the layup you select. The section that comes out is usually wider or thicker, and the weight advantage narrows to 60–70%. A real figure has to include the fixings and the supports: counting the bar alone overstates the saving.

Length, cutting and ends

Cut to the length you order. Cut with a diamond blade or by water-jet. A guillotine or an ordinary abrasive disc will not do: shearing splits the bar. The heat of an abrasive disc burns the resin and leaves a burr on the edge. The cut end is a fibre section. A solid pultrusion does not need edge sealing the way a sandwich panel does. In chemical service or long immersion a brushed resin coat on the end stops capillary wicking up the fibre. Straightness over 6000 mm is the real difficulty with this product. A pultruded bar comes out with a natural bow, and more of it the longer the bar. We hold 1 mm/m and no more than 6 mm over the piece. Anything straighter means selecting stock, or tightening the die and the puller, and both change the cost and the lead time. Packaging follows length: 6000 mm in a paper tube or a crate, shorter lengths in cartons.

Joining: drill and clamp, no threads

Drilling: 2.5 × the hole diameter is the floor for edge distance rather than a recommendation. A loaded joint wants 3–4 ×. Hole spacing at least 3 ×. Use a diamond or carbide drill with a sacrificial board behind it, so the exit face does not split. Do not expect bearing at the hole wall to carry load, carbon fibre has no yield point, and local bearing crushes it first. Clamping: friction carries the load rather than the hole wall. Large washers, at least 3 × the hole diameter, spread the pressure; a plate on either side is better still. No tapping. A thread cut straight into a flat bar will not hold. It strips after two tightenings. For a thread, bond in a metal insert, or use a through bolt with a backing plate. Bonding: abrade the grit face, wipe with acetone, epoxy structural adhesive. Lap length follows shear strength, not tensile; bond quality depends on an even bond line, and anywhere left unclamped is a weak point. No point load at the ends. A bar end is a cut fibre section and the weakest place against splitting. Keep the load at least one width in from the end, or fit an end cap.

Delivery states

  • Die face Formed against the die: flat, with light release marks. The default for visible parts and for bonding faces.
  • Grit face Post-abraded to an even roughness, prepared for bonding. Choose it on anything to be bonded and the abrading comes off the shop floor.
  • Clear coat A coat on the die face, deeper in colour, better weathering. For exposed parts.
  • Ends Sawn ±2 mm, or precision cut ±0.5 mm. Parts that assemble into something, or are held to an overall length, take precision.

Tolerance and inspection

Width ±0.2 mm Calliper
Thickness (≤3 mm) ±0.1 mm Micrometer
Thickness (>3 mm) ±0.2 mm Micrometer
Length (cut to length) ±2 mm Tape measure
Length (precision cut) ±0.5 mm Tape measure + dimensional report
Straightness 1 mm / m, ≤6 mm over the piece Surface plate + feeler gauge
Twist ≤2° / m Surface plate
Width-to-thickness ratio as ordered, deviation ±5% Recomputed from calliper readings

Common questions

Flat bar or square tube, which should I choose?

Look at whether the load runs in one direction. Bending in one direction, and fitting against a face, go to flat bar: less height, it can be bonded on, and holes are easy. Stiffness both ways, or torsion, goes to square tube: closed on four sides, an order of magnitude better in torsion. Many people fix two flat bars at right angles into a T to replace a square tube. The stiffness gets there, and two extra bonding operations with it

Can it replace a steel bar of the same size directly?

It will fit, and it will be softer. Carbon fibre has a lower modulus than steel, so deflection grows at the same size. Equal stiffness means a larger section, worked back from I_carbon = I_steel × 210 ÷ E_carbon. Weight is still on our side, but the advantage narrows from 80% to 60–70%. Steel also welds and taps, and a carbon bar does neither, so the joint detail has to be redone. Flat or on edge

How do I decide?

Bonded to a face as reinforcement: flat. Carrying bending on its own: on edge. On edge, watch lateral instability. The larger the unrestrained length over thickness, the worse it is; add a mid support, or change to square tube. The same 30×3 has I of 68 mm⁴ laid flat and 6,750 mm⁴ on edge, a hundred times apart. Fitted the wrong way round the bar does almost nothing

Will a 6000 mm bar be bowed?

It will have a natural bow. A property of pultrusion, worse the longer it is. We hold 1 mm/m, no more than 6 mm over the piece. Straighter means selecting stock, or tightening the die and the puller, and both change cost and lead time. Where the assembly is sensitive to straightness, cut shorter, or fit on edge with support

Can it be drilled, and can it be tapped?

Drilled, yes; tapped, no. Edge distance 2.5 × the hole diameter is the floor and a loaded joint wants 3–4 ×; a diamond drill, a sacrificial board behind. Load goes through friction from clamped bolts, not through bearing at the hole wall, carbon fibre has no yield point, the wall crushes first. For threads, bond in a metal insert, or use a through bolt with a backing plate

Can it be bent into a curve?

Yes, what bends is elastic, not set. Carbon fibre is elastic right up to failure, with no yield point: hold the radius above the minimum and it springs straight back. Go past it and the inner fibres crush and delaminate, a pale band showing before it breaks, how tight depends on thickness. The trade figure for epoxy pultrusion is a minimum bend radius of 100 × thickness. 0.5 mm takes a 50 mm radius and 5 mm needs 500 mm or more. In strain terms that is thickness ÷ (2 × radius) ≤ 0.5%, the same rule. 50×0.5 on a 50 mm radius lands exactly on it. Width does not enter the limit; it only sets how much force the bend takes and whether the bar twists on the way. Holding the curve is a job for the structure, bonded to a curved face, dropped into a groove, clamped under a plate. It springs back the moment the constraint comes off. A curve that arrives curved is made on a curved tool: radius pultrusion (the die travels the curve, from 40 mm radius. 300–500 mm common on thin sections), or press moulding, or winding

What is the minimum order?

500 pcs. Different lengths in the same size can go on one order, counted in total pieces. A non-standard width or thickness, holes, or end assembly are agreed per project

Can you cut to length?

Yes. 1000, 2000 and 3000 are the standard cuts and carry no extra charge; other lengths are charged per cut. A cut end is a sawn face; precision cutting to ±0.5 mm is charged separately

Can the surface be matte, or clear coated?

Yes. The default is the die face; for bonding take the grit face and save the abrading; exposed parts can take a clear coat. A flat bar is a unidirectional part with no weave, so there is no pattern option, pattern belongs to sheet and to profiles

Can you make it 100 mm wide?

No, width stops at 50 mm. Beyond that width it is a narrow sheet rather than a flat bar. At the same thickness it lies too floppy flat and too unstable on edge. Its real use overlaps sheet. Above 60 mm wide, look at carbon fibre sheet and have it cut into strips, that works out cheaper

Send us the size

Section, length, quantity and service conditions — with these in hand the quote is accurate. Upload a drawing if you have one; without one, the same figures written out will do.

No file selected

PDF, DWG, DXF, STEP, STL, ZIP or a phone photo — up to 20 MB.

The part, the material, the size — or the problem it has to solve. Drawings and photos can go in the field above.

+ Company, quantity, timeline

Used only to answer this enquiry and for related technical follow-up.

  • Company address Zhuyuan Tianhuan International, No. 76 Keji 2nd Road, High-tech Zone, Xi'an, Shaanxi, China
  • Factory Fengjing Industrial Park, Middle Section of Fengwu East Road, Huyi District, Xi'an, Shaanxi, China
  • Sales email sales@atomfrp.com
  • Phone (WeChat) +86 18191567691 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • WhatsApp +853 68617664 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • A named engineer replies within 24 hours
  • NDA can be signed before any file is sent
  • Drawings and requirements are not disclosed

Send the drawing. We will send the route.

A drawing, a photo of a failed part, or three lines of requirement is enough to start. Scope, price indication and lead time within 24 hours.

No commitment · NDA available · Reply within 24 hours

Request a quote WhatsApp