Overview

Pultruded carbon fibre channel, 20–150 mm deep, 10–75 mm flange width, wall thickness 1.5–6 mm, cut to length. The fibre runs continuously along the length, so bending is best. The three faces of the carbon fibre U channel are square to each other. The opening takes cable, a slider or a linear guide. Depth tolerance ±0.2 mm up to 50 mm and ±0.3 mm above, flange width ±0.2 mm, right angle 90° ±0.5°. Inside radius determined by the wall thickness. Weight per metre and Ix are in the table: UPN 100 steel channel weighs 10.6 kg/m. The carbon channel of the same envelope 1.41 kg/m. Outside the standard range, the same section is made as a part to drawing: see custom composite parts.

Request a quote

Where it is used

  • Equipment frames and columns
  • Mounting channels for linear guides and sliders
  • Enclosure frames and edging
  • Platform beams and joists
  • Cable runs and cable carrier channels
  • Fixing edges for panels and covers

Stock sizes in detail

Read it as depth × flange × wall. Selection turns on the Ix column, not on depth; two rows at the same depth but different wall differ in Ix by a wide margin.

Code Depth×flange Wall Length Weight kg/m Ix (cm⁴) Tolerance Note
CH-20-10-1.5 20×10 1.5 1000 0.080 0.3 ±0.2 Cable run
CH-25-12-1.5 25×12 1.5 1000 0.10 0.6 ±0.2 Cable run
CH-30-15-2 30×15 2 1000 0.16 1.5 ±0.2 Enclosure frame
CH-40-20-2 40×20 2 1000 0.23 3.7 ±0.2 Panel fixing edge
CH-40-20-3 40×20 3 1000 0.32 5.1 ±0.2 Panel fixing edge
CH-50-25-2 50×25 2 1000 0.29 7.4 ±0.2 Frame and joist
CH-50-25-3 50×25 3 1000 0.41 10.4 ±0.2 Frame and joist
CH-50-25-4 50×25 4 1000 0.53 13.1 ±0.2 Load-bearing channel
CH-60-30-3 60×30 3 1000 0.51 18.6 ±0.3 Beam
CH-60-30-4 60×30 4 1000 0.65 23.5 ±0.3 Beam
CH-76-38-3 76×38 3 1000 0.66 39.0 ±0.3 Linear guide seat
CH-76-38-4 76×38 4 1000 0.85 49.9 ±0.3 Linear guide seat
CH-80-40-4 80×40 4 1000 0.90 58.7 ±0.3 Column
CH-100-50-4 100×50 4 1000 1.15 118.2 ±0.3 Column and beam
CH-100-50-5 100×50 5 1000 1.41 143.3 ±0.3 Column and beam
CH-120-50-5 120×50 5 1000 1.56 220.9 ±0.3 Load-bearing beam
CH-150-50-6 150×50 6 1000 2.12 442.6 ±0.3 To drawing
CH-150-75-6 150×75 6 1000 2.58 598.2 ±0.3 To drawing

Three dimensions: depth, flange width, wall

The trade writes 50×25×3. 50 deep, 25 flange width, 3 wall. Depth decides bending. A channel is an open section. Its bending capacity comes mainly from the height of the web: double the depth and stiffness climbs far faster than it does with wall thickness. For stiffness, add depth before you add wall. Flange width decides what you can fit. A 25 mm flange covers an M6 bolt head and takes a 15 mm linear guide. The narrower it is, the smaller the opening and the less that goes in. Wall decides whether you can drill and whether it can take load. At 1.5 mm, bonding or riveting only. At 2–3 mm, M5–M6 holes. From 4 mm up you can talk about load-bearing and tapping (carbon fibre is not threaded, see the FAQ). The three dimensions are not mixed at random: the deeper the channel, the more the wall has to follow, or the flange buckles first. The combinations in our table are the ones that have been checked for buckling.

Opening out or opening in — decide at assembly

Opening out: bolts, cable or a slider sit inside the channel and the outside face is flat. Columns, guide rail seats and cable runs all use this way up. Opening in: two channels face each other to form a closed cavity that takes ballast, core material or a joint detail. Common in display work and enclosures. Opening down: as a beam, with cable or a cable carrier hanging inside, and no water collecting. If the direction will not settle, draw the assembly sequence first. Often it is not a selection question at all: the bolt has to go in first. That locks the opening direction.

The price of an open section: spring-back and twist

A C section is an open section, the same family as an angle, and it carries the same two built-in problems. Spring-back: after curing the two flanges open or close slightly and the right angle is not exactly 90°. We hold 90° ±0.5°, and assembly absorbs the rest in the adhesive layer or a shim. Twist: a long length rotates slowly along its length, more so the thinner and longer it is; we hold 1°/m. For long guide rail seats, put the requirement on the drawing and we check it over the working length. For a long beam that must not twist at all, use a square tube, mitred at the corners. A closed section has neither problem.

Weight per metre: how it compares with steel channel

Carbon fibre at 1.55 and steel at 7.85 gives about an 80% reduction at equal volume. Every band in the table carries kg/m, for direct comparison:

  • 50×25×3: carbon fibre 0.41 kg/m, steel channel 2.24 kg/m
  • 100×50×5: carbon fibre 1.41 kg/m, Ix 143.3 cm⁴; UPN 100 steel channel 10.6 kg/m
  • 150×75×6: carbon fibre 2.58 kg/m, steel channel 17.4 kg/m
But this is equal volume. Modulus depends on fibre grade and fibre volume fraction, and changes with the material you choose, so we do not publish one number. Equal stiffness works back from I_carbon = I_steel × 210 / E_carbon, with 210 GPa for steel as a published standard value and E_carbon taken from the layup you select. Equal stiffness usually means a deeper channel. For a replacement, give us load, span and allowed deflection and we work back from stiffness, better than estimating by volume.

Length, cutting and end facing

Standard lengths are 1000 mm and 2000 mm, with other lengths cut to order; longer needs a joint. Cutting. Water-jet leaves a clean edge without chipping, the first choice for thin wall and visible parts. Thick wall and long runs take sawing, leaving 0.2 mm on the end to machine back. End squareness ±0.5°. A channel end is three faces, web plus two flanges. All three have to be square for a frame to close up without a gap.

Delivery states

  • Natural The pultruded surface as it comes: smooth, dark grey to black, unpatterned. The default for structural and internal parts.
  • Clear coat A coat over the natural surface, gloss or semi-matte. More resistant to soiling.
  • Matte The same coating system, flattened; less reflection, common on exposed frames and display work.
  • Painted Painted to a project colour reference; the colour and the gloss are yours, and we control flatness and adhesion.

Tolerance and inspection

Depth (≤50 mm) ±0.2 mm Calliper + dimensional report
Depth (>50 mm) ±0.3 mm Calliper
Flange width ±0.2 mm Calliper
Wall thickness ±5% (thin wall counted by plies) Calliper / ultrasonic
Right angle (web to flange) 90° ±0.5° Engineer's square + feeler gauge
Inside radius Determined by the wall thickness (of the same order) Profile gauge / projector
Twist ≤1° / m Surface plate measurement
Straightness 1 mm / m Surface plate + feeler gauge
Length (cut to length) ±0.1 mm Water-jet guided / CNC
End squareness ≤0.5° Engineer's square
Hole position and slotting ±0.01 mm CMM

Common questions

Channel or square tube — which should I choose?

A channel is an open section with three sides closed: it takes fittings on two directions but twists more than a square tube. A square tube is closed on four sides and resists torsion best, but nothing can be hidden inside it. For cable, sliders and a guide slot, use the channel; for torsion and a closed box, use the square tube

Can it replace a steel channel directly?

The dimensions match; the stiffness does not. Carbon fibre modulus depends on the layup, so at the same size it is always softer than steel. Give us load, span and allowed deflection and we work back to depth and wall — do not swap the steel designation straight across

Can the opening be customised?

Yes. The flanges can be unequal (such as 100×50×40×5), and the opening follows the flange width. Made to drawing on a new die, which takes 5–7 days

Can I fit a linear guide?

Yes. A 15 mm linear guide usually mounts on a flange of 25–38 mm, and our 40×20, 50×25 and 76×38 all work as guide seats, drilled to the guide maker's hole pitch at ±0.01 mm

Can you drill and tap it?

Drilling, notching and counterboring, all at ±0.01 mm. Carbon fibre is not threaded: for a bolted joint use through bolts with washers, and for a blind hole bond an insert in

Will it twist?

It will — the standard complaint about open sections — and we hold 1°/m. For long guide rail seats, put the twist requirement on the drawing and we check it over the working length. It will — the standard complaint about open sections — and we hold 1°/m. For long guide rail seats, put the twist requirement on the drawing and we check it over the working length. Can you drill 1.

Can you drill 5 mm wall?

You can, but only with small bolts (M4 and under) and washers, with the tightening torque controlled. At 1.5 mm, bonding or riveting suits it better; for M6, go to 3 mm and above

Is there any carbon weave?

No. Pultrusion gives a unidirectional finish — a layer of resin, dark grey to black. Carbon weave means overwrapping 3K prepreg, or changing to a moulded part

What are the MOQ and lead time?

500 pcs. Normal batches ship in 15–20 days; a non-standard depth, flange or wall needs a new die, which takes 5–7 days

Can you make glass fibre?

Yes, in the same construction — lower stiffness and lower cost, common for insulating parts and low-frequency structural parts. Quoted through the glass fibre product line

Send us the size

Section, length, quantity and service conditions — with these in hand the quote is accurate. Upload a drawing if you have one; without one, the same figures written out will do.

No file selected

PDF, DWG, DXF, STEP, STL, ZIP or a phone photo — up to 20 MB.

The part, the material, the size — or the problem it has to solve. Drawings and photos can go in the field above.

+ Company, quantity, timeline

Used only to answer this enquiry and for related technical follow-up.

  • Company address Zhuyuan Tianhuan International, No. 76 Keji 2nd Road, High-tech Zone, Xi'an, Shaanxi, China
  • Factory Fengjing Industrial Park, Middle Section of Fengwu East Road, Huyi District, Xi'an, Shaanxi, China
  • Sales email sales@atomfrp.com
  • Phone (WeChat) +86 18191567691 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • WhatsApp +853 68617664 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • A named engineer replies within 24 hours
  • NDA can be signed before any file is sent
  • Drawings and requirements are not disclosed

Send the drawing. We will send the route.

A drawing, a photo of a failed part, or three lines of requirement is enough to start. Scope, price indication and lead time within 24 hours.

No commitment · NDA available · Reply within 24 hours

Request a quote WhatsApp