Overview

For torsion, or the same stiffness in every direction, take round tube; for flat faces and bolts that clamp properly, take box section. Round wins on load and loses on connection: a curved face gives line contact only, and tightening dents the wall. It needs a sleeve or a saddle. Outside diameter 4–150 mm, wall 1–6 mm, cut to the length you need. The trade also writes GRP tube and FRP tube for the same product. On a drawing or a purchase order GRP is the least ambiguous. Against carbon fibre tube it is less stiff and heavier, but far cheaper. It is insulating, RF transparent and non-magnetic, none of which carbon fibre can do. A metal part has to be coated against corrosion, and this does not. A metal part needs a sleeve to insulate it, and this already is one, the resin follows the duty. Unsaturated polyester, vinyl ester, epoxy and polyurethane are all made here, and they differ widely in corrosion and temperature. Settle the medium and the temperature first, then the system. Read a size as outside diameter × wall. 50 × 5 is 50 outside, 5 wall, 40 bore. Where the catalogue stops and the drawing starts, see custom composite parts.

Request a quote

Where it is used

  • Handrails and guardrails: 50 mm tube with moulded or machined fittings, in chemical plants, sewage works, substations and offshore platforms
  • Electrical insulation: cable conduit, transformer and switchgear supports, insulated operating rods
  • Antennas and test: antenna masts, antenna housings, RF test frames
  • Structural frames: equipment frames, walkway railings, platform supports
  • Corrosion-resistant pipework: low-pressure fluid, extraction and dosing lines
  • Rods: tent poles, flagpoles, kite rods, model frames

Stock sizes in detail

The steps are set by the bores of standard fittings and clamps: 9.5, 12.5, 19, 25, 38 and 50 each have a matching moulded tee, elbow and base flange.

Code OD mm ID mm Wall mm Section mm² kg/m Note
FG-04-10 4 2 1.0 9.4 0.019 Model frames
FG-05-10 5 3 1.0 12.6 0.025 Light rod
FG-06-15 6 3 1.5 21.2 0.042 Light rod, insulating rod
FG-08-10 8 6 1.0 22.0 0.044 Kite rod
FG-08-15 8 5 1.5 30.6 0.061 Kite rod, models
FG-095-15 9.5 6.5 1.5 37.7 0.075 Light rod, insulating rod
FG-125-15 12.5 9.5 1.5 51.8 0.104 Tent pole, light rod
FG-16-20 16 12 2.0 88.0 0.176 Insulating support
FG-19-20 19 15 2.0 106.8 0.214 Insulating support, bracket
FG-22-20 22 18 2.0 125.7 0.251 Support rod, railing
FG-25-20 25 21 2.0 144.5 0.289 Thin wall, light duty
FG-25-30 25 19 3.0 207.4 0.415 Standard structure, bracket
FG-31-25 31 26 2.5 223.8 0.448 Handrail, support
FG-38-30 38 32 3.0 329.9 0.660 Guardrail post
FG-485-30 48.5 42.5 3.0 428.8 0.858 Takes standard fittings
FG-50-50 50 40 5.0 706.9 1.414 The handrail size
FG-60-40 60 52 4.0 703.7 1.407 Guardrail post
FG-76-50 76 66 5.0 1115.3 2.231 Large-diameter structure
FG-89-50 89 79 5.0 1319.5 2.639 Large-diameter structure
FG-100-50 100 90 5.0 1492.3 2.985 Large-diameter structure
FG-114-60 114 102 6.0 2035.8 4.072 Large diameter, made to drawing
FG-150-60 150 138 6.0 2714.3 5.429 Large diameter, made to drawing

Environment and properties: where it beats metal and carbon fibre

Electrical insulation. High volume resistivity, which makes it the usual material for insulating parts, cable conduit and transformer supports. Carbon fibre conducts, and this is one only glass fibre can give, rF transparent, the signal passes through. Antenna housings, antenna masts and test-equipment supports are built from it because nothing is blocked. Metal cannot do it at all, and carbon fibre screens the signal, no rust, and it resists chemicals. It does not react with water or oxygen. On a coast, at a sewage works. On a plating line or in a chemical plant a metal part shows rust within months while this is still the colour it was made. At room temperature it resists most acid, alkali and salt solutions, oils and most solvents. Strong alkalis and strongly oxidising acids attack the resin, so check the medium, its concentration and its temperature when selecting. Corrosion and temperature start with the resin system: all of these are made in house. The dimensions stay the same while the resin sets the service life. That decision comes before wall thickness, state the medium, its concentration and its temperature first. - Unsaturated polyester: the table default is isophthalic (iso). Resists hydrolysis and weak acids and is the one for sewage works, coastal sites and anything washed frequently. Ortho is a step cheaper and enough for dry conditions and ordinary structure, but it hydrolyses in permanent immersion. Lowest cost of the group, noticeable shrinkage, ordinary toughness and temperature rather than for strong acids or alkalis, high temperature or repeated loading. - Vinyl ester: the strongest chemical resistance, for plating, chlor-alkali, sodium hypochlorite and mixed acids. Dearer than polyester, and it processes much like it. - Epoxy: the best mechanical performance and fatigue resistance, and the highest temperature band, for structural parts and parts loaded repeatedly. Highest unit price, slow cure, slowest throughput. - Polyurethane: the best toughness, impact and abrasion resistance, a fast pultrusion line, and no styrene. Temperature and strong-alkali resistance sit below epoxy; it suits parts that need toughness rather than the highest stiffness, non-magnetic. It does not carry a magnetic field, so it introduces no disturbance next to MRI, electron microscopes or precision sensing, light. Finished density is around 2.0 g/cm³. The glass itself is 2.5, brought down by the resin. A quarter of steel and a little over two thirds of aluminium. Heavier than carbon fibre, far lighter than metal, and a fraction of the price, colour is in the resin. Yellow, grey and black are body colours, pigmented into the resin rather than applied on top. Scratch it or cut it and the section is the same colour, no white core showing through. Guardrail and fencing are where this matters most: a painted or filmed tube shows bare material the first time it is knocked, outdoors. Every resin matrix is affected by ultraviolet, and long exposure powders the surface and exposes fibre. A UV-resistant clear coat, or a resin system with UV stabilisers in it, holds that off with no effect on tube strength.

Forming: pultrusion, filament winding, roll wrapping

Pultrusion. Fibre bundles are impregnated and pulled through a heated die in one pass. All the fibre is axial, and length is set by machine stroke and transport, cut to the length you need. Most fibreglass tube on the market is made this way; guardrails, insulation and structural frames all use it. Even wall, smooth surface, lowest unit price, filament winding. Fibre is laid on the mandrel at an angle, with hoop and longitudinal plies controlled separately. Suits parts that must resist internal pressure or torsion, and suits large diameters. Change the angle and the balance between hoop and axial performance changes with it, roll wrapping. Prepreg or fabric is wrapped on a mandrel, which suits thin walls, small batches and unusual diameters. Wall accuracy is not as good as pultrusion, but small-diameter thin-wall work often goes this way, choosing. Length, unit price and axial stiffness go to pultrusion. Pressure, hoop strength and diameters above 100 go to winding. Small-batch thin wall, or one odd diameter that has to be exactly that, goes to roll wrapping,

Wall, bore and straightness

Wall. Normally 1–6 mm, stepped with outside diameter. A thin wall is light with a large bore, which suits shafts inside it and cable runs. A thick wall takes compression and bending, which suits posts and load-bearing parts, bore. The bore follows from outside diameter and wall, bore = outside diameter − 2 × wall. The mandrel sets it, so the bore tolerance is quoted together with the wall, straightness. Pultruded parts are held to 1 mm/m, and the total accumulates with length, around 6 mm over a 6 m length. Assembly takes up in joint clearance. Straighter means selecting stock, or shortening the single length, roundness, normally 0.2 mm. Thin-wall large-diameter tube flattens most easily, so do not stack it too high in store.

Handrail tube, 50 mm: the case on its own

In the guardrail systems of chemical plants, sewage works, substations and offshore platforms. The 50 mm line is the biggest of them: one tube and a set of fittings, moulded or machined, sold as a kit by diameter. The firms making handrail systems do not make the tube. They buy tube, buy fittings, and sell a system, main size. 50 outside, 5 wall, 40 bore, usually run at 6000 mm and cut to site dimensions if you prefer. It takes the common moulded tees, elbows and base flanges, drilled to the fitting pattern. Why handrail tube is 50 and not 48.3. The bore of a handrail fitting is made for 50 mm. The tube cannot go down a size or it will not clamp, and cannot go up or it will not fit. The wall is fixed by the same fit. What other systems use does not change the one thing you have to check: 42.4 and 48.3 outside diameters are also in the market. With a different fitting family. The same nominal figure does not make the two interchangeable. Whatever the other side quotes, the safe move is to measure the fitting bore, surface. Guardrail is usually yellow or grey, and the colour is pigmented into the resin rather than applied on top. A cut face or a scratch shows the same colour, outdoors, add a UV-resistant clear coat, cutting and drilling. The water-jet guided laser cuts to length and drills holes. A square end, no burning and no breakout, length ±0.1 mm, holes go on the fitting drawing. Hole spacing in handrail systems is standardised, so machining to the system maker's drawing means it bolts straight on site,

Jointing: bonding, drilling, bolts

Bonding. Glass-fibre tube has a low surface energy, so it has to be abraded and wiped clean before bonding. A part is to be bonded we prepare the bonding face at the factory, so it arrives ready for adhesive. Epoxy structural adhesive is the most reliable, with a lap of at least one tube diameter and loaded joints checked against shear strength. Tube to tube needs an internal sleeve; a butt joint on the end faces alone will not do, drilling. Holes go on the fitting drawing, with an edge distance from 2.5 × the hole diameter and 3–4 × on a loaded joint. Drilling and water-jet guided holes are both done in house, to the hole tolerance on the drawing, bolts. Clamping works through friction, so do not count on bearing at the hole wall. Use large washers or a plate either side to spread the pressure, and add metal corner protection where the joint comes apart repeatedly, no tapping. The wall is too thin and a thread cut straight into it will not hold. For a thread, bond a metal insert in, or use a through bolt with a backing plate, threaded ends. Where a system needs a threaded end, the metal female insert is bonded into the tube end rather than cut into the wall.

Delivery states

  • Natural (die face) The surface off the die, cream to pale green, smooth, and can be bonded directly
  • Grit face Abraded, saving a step before bonding
  • Pigmented resin Yellow, grey, black and so on, coloured through the resin — the cut face matches, with no gel coat and no paint
  • UV-resistant clear coat One coat for exposed parts; blocks UV and leaves the colour alone
  • Machined Cut, drilled and slotted to drawing
  • Assembly Supplied assembled with fittings, flanges and joints

Tolerance and inspection

Outside diameter ±0.2 mm ±0.3 mm
Inside diameter ±0.3 mm ±0.4 mm
Wall thickness ±0.2 mm ±0.3 mm
Length (sawn) ±2 mm ±2 mm
Length (water-jet guided laser) ±0.1 mm ±0.1 mm
Straightness 1 mm/m, accumulating with length 1.5 mm/m
Roundness 0.2 mm 0.3 mm

Common questions

Fibreglass tube or carbon fibre tube, which should I choose?

Whichever matters more to you. Stiffness and light weight go to carbon fibre; insulation, RF transparency and cost control go to glass fibre. The last one is the practical one. On the same 50 mm tube, glass fibre is a fraction of the carbon price. For guardrail or bracketry that does not need to be as light as possible, carbon fibre is money wasted

How does it compare with steel tube?

A quarter of the weight, no rust, insulating, non-magnetic. The price is stiffness, steel is stiffer at the same size. Equal stiffness means a thicker wall or a larger diameter. The weight advantage narrows, but it stays obvious.

Can it be used outdoors?

Yes, with UV protection. The resin matrix itself does not take sunlight: long exposure powders the surface and exposes fibre, and a UV-resistant clear coat holds that off. A resin system with UV stabilisers in it lasts longer outside. Colour is covered in the next answer

What temperature can it take?

The resin and its curing system decide. We quote a range rather than a guarantee: polyester and polyurethane normally to around 80 °C, vinyl ester close to 100 °C, epoxy higher. Depending on hardener and post-cure. Settle the service temperature of the medium first, then pick the system

Why is the 50 mm size 5 mm wall?

Handrail fittings are made for 50 outside and 40 bore, and a 5 mm wall is what that produces. Thin the wall and the tube rattles in the fitting; thicken it and it will not go in, this size does not flex

Which resin should I use?

Settle the medium, its concentration and its temperature first, then match. Dry or ordinary outdoor duty, weak acids and alkalis, salt spray: isophthalic polyester is enough, and it is the table default, ortho takes cost out. Keep it away from permanent immersion. Plating, chlor-alkali, sodium hypochlorite, mixed acids, main sewage lines: vinyl ester, structural parts, repeated loading, temperature: epoxy. Toughness, impact, indoor parts, a shop with styrene controls: polyurethane. If it is not clear, send the medium, concentration and temperature and we will advise on the duty

Can it be drilled, and can it be tapped?

Drilled, yes, water-jet guided holes, to the drawing, in house. Tapped, no: the wall is thin and the interlaminar strength will not hold a thread. Where a thread is needed we bond a metal insert in, fitted in house.

How much does one weigh?

The table carries kg/m, on the polyester default. 50 × 5 is 1.414 kg/m, so a 6000 mm length is 8.48 kg; epoxy or polyurethane is reweighed per batch. An order's weight is length × that figure, and freight follows it

What is the MOQ?

Agreed per project. Small batches of stock sizes are accepted; a non-standard diameter needs a die, and the MOQ follows the tooling amortisation

Can you supply colours?

Yes. Natural is cream to pale green, the natural colour of resin and fibre. Yellow, grey and black are pigmented into the resin, so there is no gel coat and no paint. The cut face and any scratch match. A transparent or translucent tube needs a different resin system, and it loses some stiffness

Send us the size

Section, length, quantity and service conditions — with these in hand the quote is accurate. Upload a drawing if you have one; without one, the same figures written out will do.

No file selected

PDF, DWG, DXF, STEP, STL, ZIP or a phone photo — up to 20 MB.

The part, the material, the size — or the problem it has to solve. Drawings and photos can go in the field above.

+ Company, quantity, timeline

Used only to answer this enquiry and for related technical follow-up.

  • Company address Zhuyuan Tianhuan International, No. 76 Keji 2nd Road, High-tech Zone, Xi'an, Shaanxi, China
  • Factory Fengjing Industrial Park, Middle Section of Fengwu East Road, Huyi District, Xi'an, Shaanxi, China
  • Sales email sales@atomfrp.com
  • Phone (WeChat) +86 18191567691 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • WhatsApp +853 68617664 Email and forms answered 24/7; phone Mon–Fri 09:00–18:00 GMT+8
  • A named engineer replies within 24 hours
  • NDA can be signed before any file is sent
  • Drawings and requirements are not disclosed

Send the drawing. We will send the route.

A drawing, a photo of a failed part, or three lines of requirement is enough to start. Scope, price indication and lead time within 24 hours.

No commitment · NDA available · Reply within 24 hours

Request a quote WhatsApp