Reference image. The actual surface and colour depend on the resin and the finish.
Overview
Where assembly comes first, take box section. Four flat faces: a washer sits and clamps, and angle brackets, rails and panels go straight on. A round tube is a curved face, so a bolt gets line contact only and tightening dents the wall. Box section is pultruded continuously with the fibre axial, so longitudinal stiffness and bending are best. The hoop direction is carried by the resin and the layup. Machine frames, gantries, guardrail posts and equipment bases are where box section goes. Side 25 to 150 mm, wall 2 to 10 mm, four flat faces, so drilling, slotting and fitting angle brackets need no separate adapter. The four corners are where stress concentrates. Wall tolerance and corner radius decide whether a joint can be pulled up tight. Quote the wall alongside the size: a side dimension on its own is not a complete specification. Insulation and chemical resistance come from the resin. Box section usually runs unsaturated polyester; vinyl ester for acids and alkalis; epoxy where more strength and dimensional stability are needed. All of them can be made, at different price and lead time, state the medium and the service temperature at order. Cutting, drilling, milling and water-jet guided laser cutting are all done in house. Glass fibre wears tooling faster than carbon fibre, which shows up in the machining charge and not in the tolerance. A cut end exposes fibre, so parts for outdoor or damp service are sealed before they ship. Outside the standard range, the same section is made as a part to drawing: see custom composite parts.
Chemical and effluent: handrails, guardrails, walkway supports
General structure: beams, edge frames, edge supports
Stock sizes in detail
kg/m is section area × density at 2.0 g/cm³; the section area is given so you can check it.
Side mm
Wall mm
Section area mm²
kg/m
Typical use
25 × 25
3
264
0.53
Guardrail, light frame
30 × 30
2
224
0.45
Decorative frame, cover
38 × 38
2
288
0.58
Light bracket
38 × 38
3
420
0.84
Equipment frame, bracket
38 × 38
5
660
1.32
Load-bearing frame
40 × 30
3
384
0.77
Beam, edge frame
40 × 30
5
600
1.20
Load-bearing beam
44 × 44
6
912
1.82
Post
50 × 20
4
496
0.99
Flat beam, edge support
50 × 50
3
564
1.13
Guardrail post, platform support
50 × 50
4.5
819
1.64
Load-bearing post
51 × 51
6.35
1134
2.27
Heavy-duty post
60 × 60
4.5
999
2.00
Main post, frame
100 × 50
8
2144
4.29
Heavy-duty beam
100 × 100
4
1536
3.07
Main structure, cable tray support
kg/m is section area × density at 2.0 g/cm³: for a square section A = a² − (a−2t)², for a rectangle A = ab − (a−2t)(b−2t).
The figure excludes the surface veil and the resin-rich layer, so actual weight runs 3–5% above the table; add 5% when quoting freight.
Sides and walls outside the table are scheduled to drawing.
Box section or round tube: choose by how it assembles
Where the load is the same, take round tube, where assembly comes first. Take box section. A round tube has the same bending stiffness in every direction and the best torsion, but the surface is curved. A bolt gets line contact only and tightening dents the wall. It needs a sleeve, a saddle or potting. Box section has flat faces: a washer clamps, and angle brackets, hinges, rails and panels all go straight on. Light load, short span and assembly-led structure: box section saves labour. Heavy load, long span and torsion: round tube saves material. Both are made, and the two are commonly mixed, box section for posts, round tube for beams.
Joints: wall, hole position, internal cavity
Box section carries load mainly at its four corners. An under-thick wall cracks at the corner the moment a bolt is tightened. Read the wall off the joint type. Self-tapping screws or blind rivets need 3 mm or more, or the thread will not bite. Through bolts with washers work from 2.5 mm, with the torque controlled. For a thread, the wall is not tapped. An insert or a through bolt instead. Size the holes on bearing, not on tensile. Glass bearing strength is a fraction of axial tensile, so a short edge distance tears when the bolt is tightened. Start with an edge distance of three hole diameters, and four is safer; leave three diameters or more between holes as well. The larger the hole, the more the absolute edge distance has to grow with it. Box section is hollow, so how the nut goes in has to be settled at selection, not at assembly. In the middle of a long length there is no access. The options are: feed it in from the end, use a rivet nut, or through-bolt so both walls clamp together. The first two demand more wall; the through bolt is the most secure, at the cost of a visible head on the far side. Where metal meets glass, watch galvanic corrosion too. The glass itself insulates, so use an insulating washer or matching metals, and do not let stainless steel bite directly into aluminium.
Choosing the resin
Unsaturated polyester is the standard choice: lowest price, resistant to acids, alkalis and most solvents, enough for general framing, guardrail and supports. Vinyl ester resists chemicals better, and is the one for strong acids, sodium hypochlorite and wet chlorine, common in chemical plants and sewage works. Epoxy has the best mechanical strength and dimensional stability and the lowest water absorption, at a higher unit price and a slower cure. It goes where precision or long-term immersion demands it. Changing system leaves the MOQ the same and adds to the lead time.
Post-machining: done in house, arrives as a part
Lengths are cut to drawing, water-jet guided laser takes cut-to-length and holes, CNC mills notches. Slots and end chamfers. The ends that need sealing are sealed before dispatch. It arrives as a part and goes straight into assembly. Cutting: water-jet guided laser for cut-to-length and holes, no burning or breakout at the edge, length ±0.1 mm. Sawn to ±2 mm, CNC-milled edge ±0.2 mm. Holes and slots: hole position ±0.01 mm; notches, slots and end chamfers to drawing. Edge distance has to be enough, glass bearing strength is a fraction of axial tensile. A short edge tears when the bolt is tightened, Ends: a cut end exposes fibre. Parts for outdoor, damp or chemical service are sealed in house with resin of the same system, or with an end cap. Threads: the wall is not tapped, because interlaminar shear will not hold a thread. Threaded parts take an insert or a through bolt with a back plate, fitted in house. Glass fibre wears tooling faster than carbon fibre, which shows up in the machining charge and not in the tolerance. Where the part combines with metal or inserts it ships as an assembly, with the fit confirmed at first article. This is done on our own profiles only. Customer-supplied finished parts are not machined, but customer-supplied fibre or prepreg is processed into product.
Delivery states
Full length Supplied at standard length, protective film intact
Cut to length Cut to drawing, ±2 mm
Precision cut CNC-milled edge, ±0.2 mm
Drilled and slotted To drawing, hole position to drawing
Ends Sawn edge / CNC chamfer / sealed end
Assembly Combined with metal parts and inserts, batch after first-article approval
Tolerance and inspection
Side
±0.5%, minimum ±0.2 mm, maximum ±0.75 mm
Small sections take the minimum, large ones the percentage
Wall, 2 mm band
±0.15 mm
Thin wall; through bolts with washers
Wall, 3 mm band
±0.20 mm
The minimum band for self-tapping and rivets
Wall, 5 mm band
±0.35 mm
Common on load-bearing joints
Wall, 10 mm band
±0.45 mm
Heavy structures
Angle
±1.5°
The four right angles; decides whether brackets sit flat
Straightness
1.5 mm/m
Accumulates with length on long spans
Twist
Wall below 5 mm: 1.5°/m; 5 mm and above: 1.0°/m
Thin walls twist more readily
Sawn length
+50 / −0 mm
Stock, allowance for machining
Water-jet guided cut
±0.1 mm
Cut to length and holes
Hole position
±0.01 mm
To drawing
CNC-milled edge
±0.2 mm
Precision-cut parts
Common questions
Box section or round tube?
Round tube where the load is the same in every direction, box section where assembly comes first. Round has even stiffness and good torsion but only line contact at a bolt; box section has flat faces, and a washer clamps them
What is the thinnest wall you can make?
2 mm as standard. Below 3 mm we do not advise self-tapping screws or blind rivets, the thread will not bite. Use through bolts with washers and control the torque
How much does a 6 m length weigh?
Multiply the kg/m in that row by 6. The table figure comes from section area × density and excludes the surface veil and the resin-rich layer. The actual weight runs 3–5% above it, add 5% when quoting freight
How far should a hole be from the edge?
From three hole diameters; four is safer. Glass bearing strength is low, so a short edge distance tears the hole when the bolt is tightened. The larger the hole the more the absolute distance has to grow
What if I need a nut in the middle of a long length?
With no access there are only a few routes: feed it in from the end, use a rivet nut, through-bolt so both walls clamp. Settle it at selection rather than at assembly
What is the side tolerance?
±0.5%, minimum ±0.2 mm, maximum ±0.75 mm
What is the wall tolerance?
By band: 2 mm ±0.15, 3 mm ±0.20, 5 mm ±0.35, 10 mm ±0.45
Can you cut an internal thread?
The wall is not tapped: interlaminar shear will not hold a thread and repeated assembly strips it. Use an insert or a through bolt, fitted in house
Can it be laser cut?
Yes. Water-jet guided laser cuts to length and drills holes without burning or breakout, length ±0.1 mm, hole position ±0.01 mm
Will it age outdoors?
UV absorbers go into the resin, and the surface can be grit-finished or coated. For long exposure, choose the surface treatment for the service life you need
Do the ends need treatment?
Yes for outdoor, damp or chemical service, and we seal them in house with resin of the same system or an end cap
Can I choose the colour?
Colour is pigmented in the resin, grey, green, yellow and black are common, and the cut face matches. Shade and minimum order are confirmed per batch
Can you make rectangular tube?
Yes. Side ratio and wall to drawing, with the short side limited by bending
What is the MOQ?
Full lengths are the minimum; cut lengths are quoted per piece, and drilled or slotted parts per piece
Send us the size
Section, length, quantity and service conditions — with these in hand the quote is accurate. Upload a drawing if you have one; without one, the same figures written out will do.
Company addressZhuyuan Tianhuan International, No. 76 Keji 2nd Road, High-tech Zone, Xi'an, Shaanxi, China
FactoryFengjing Industrial Park, Middle Section of Fengwu East Road, Huyi District, Xi'an, Shaanxi, China